Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
BMC Infect Dis ; 23(1): 447, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37400753

RESUMEN

BACKGROUND: To improve tuberculosis (TB) diagnosis, the World Health Organisation (WHO) has called for a non-sputum based triage test to focus TB testing on people with a high likelihood of having active pulmonary tuberculosis (TB). Various host or pathogen biomarker-based testing devices are in design stage and require validity assessment. Host biomarkers have shown promise to accurately rule out active TB, but further research is required to determine generalisability. The TriageTB diagnostic test study aims to assess the accuracy of diagnostic test candidates, as well as field-test, finalise the design and biomarker signature, and validate a point-of-care multi-biomarker test (MBT). METHODS: This observational diagnostic study will evaluate sensitivity and specificity of biomarker-based diagnostic candidates including the MBT and Xpert® TB Fingerstick cartridge compared with a gold-standard composite TB outcome classification defined by symptoms, sputum GeneXpert® Ultra, smear and culture, radiological features, response to TB therapy and presence of an alternative diagnosis. The study will be conducted in research sites in South Africa, Uganda, The Gambia and Vietnam which all have high TB prevalence. The two-phase design allows for finalisation of the MBT in Phase 1 in which candidate host proteins will be evaluated on stored serum from Asia, South Africa and South America and on fingerstick blood from 50 newly recruited participants per site. The MBT test will then be locked down and validated in Phase 2 on 250 participants per site. DISCUSSION: By targeting confirmatory TB testing to those with a positive triage test, 75% of negative GXPU may be avoided, thereby reducing diagnostic costs and patient losses during the care cascade. This study builds on previous biomarker research and aims to identify a point-of-care test meeting or exceeding the minimum World Health Organisation target product profile of a 90% sensitivity and 70% specificity. Streamlining TB testing by identifying individuals with a high likelihood of TB should improve TB resources use and, in so doing, improve TB care. TRIAL REGISTRATION: NCT04232618 (clinicaltrials.gov) Date of registration: 16 January 2020.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis , Humanos , Sistemas de Atención de Punto , Triaje , Tuberculosis/diagnóstico , Pruebas en el Punto de Atención , Sensibilidad y Especificidad , Biomarcadores
2.
iScience ; 26(1): 105873, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36590898

RESUMEN

Diagnostic services for tuberculosis (TB) are not sufficiently accessible in low-resource settings, where most cases occur, which was aggravated by the COVID-19 pandemic. Early diagnosis of pulmonary TB can reduce transmission. Current TB-diagnostics rely on detection of Mycobacterium tuberculosis (Mtb) in sputum requiring costly, time-consuming methods, and trained staff. In this study, quantitative lateral flow (LF) assays were used to measure levels of seven host proteins in sera from pre-COVID-19 TB patients diagnosed in Europe and latently Mtb-infected individuals (LTBI), and from COVID-19 patients and healthy controls. Analysis of host proteins showed significantly lower levels in LTBI versus TB (AUC:0 · 94) and discriminated healthy individuals from COVID-19 patients (0 · 99) and severe COVID-19 from TB. Importantly, these host proteins allowed treatment monitoring of both respiratory diseases. This study demonstrates the potential of non-sputum LF assays as adjunct diagnostics and treatment monitoring for COVID-19 and TB based on quantitative detection of multiple host biomarkers.

3.
Biology (Basel) ; 10(12)2021 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-34943175

RESUMEN

Nonhuman primates (NHPs) are relevant models to study the pathogenesis of tuberculosis (TB) and evaluate the potential of TB therapies, but rapid tools allowing diagnosis of active pulmonary TB in NHPs are lacking. This study investigates whether low complexity lateral flow assays utilizing upconverting reporter particles (UCP-LFAs) developed for rapid detection of human serum proteins can be applied to detect and monitor active pulmonary TB in NHPs. UCP-LFAs were used to assess serum proteins levels and changes in relation to the MTB challenge dosage, lung pathology, treatment, and disease outcome in experimentally MTB-infected macaques. Serum levels of SAA1, IP-10, and IL-6 showed a significant increase after MTB infection in rhesus macaques and correlated with disease severity as determined by pathology scoring. Moreover, these biomarkers could sensitively detect the reduction of bacterial levels in the lungs of macaques due to BCG vaccination or drug treatment. Quantitative measurements by rapid UCP-LFAs specific for SAA1, IP-10, and IL-6 in serum can be utilized to detect active progressive pulmonary TB in macaques. The UCP-LFAs thus offer a low-cost, convenient, and minimally invasive diagnostic tool that can be applied in studies on TB vaccine and drug development involving macaques.

4.
Nat Commun ; 12(1): 6181, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34702841

RESUMEN

The rhesus macaque provides a unique model of acquired immunity against schistosomes, which afflict >200 million people worldwide. By monitoring bloodstream levels of parasite-gut-derived antigen, we show that from week 10 onwards an established infection with Schistosoma mansoni is cleared in an exponential manner, eliciting resistance to reinfection. Secondary challenge at week 42 demonstrates that protection is strong in all animals and complete in some. Antibody profiles suggest that antigens mediating protection are the released products of developing schistosomula. In culture they are killed by addition of rhesus plasma, collected from week 8 post-infection onwards, and even more efficiently with post-challenge plasma. Furthermore, cultured schistosomula lose chromatin activating marks at the transcription start site of genes related to worm development and show decreased expression of genes related to lysosomes and lytic vacuoles involved with autophagy. Overall, our results indicate that enhanced antibody responses against the challenge migrating larvae mediate the naturally acquired protective immunity and will inform the route to an effective vaccine.


Asunto(s)
Schistosoma mansoni/fisiología , Esquistosomiasis mansoni/inmunología , Animales , Anticuerpos Antihelmínticos/inmunología , Anticuerpos Antihelmínticos/farmacología , Antígenos Helmínticos/inmunología , Modelos Animales de Enfermedad , Epigénesis Genética/efectos de los fármacos , Femenino , Genes de Helminto/genética , Granulocitos/inmunología , Histonas/metabolismo , Interacciones Huésped-Parásitos/inmunología , Larva/efectos de los fármacos , Larva/genética , Larva/crecimiento & desarrollo , Linfocitos/inmunología , Macaca mulatta/inmunología , Macaca mulatta/parasitología , Masculino , Recuento de Huevos de Parásitos , Reinfección/inmunología , Esquistosomiasis mansoni/parasitología
5.
iScience ; 24(1): 102006, 2021 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-33490914

RESUMEN

To end the decade-long, obstinately stagnant number of new leprosy cases, there is an urgent need for field-applicable diagnostic tools that detect infection with Mycobacterium leprae, leprosy's etiologic agent. Since immunity against M. leprae is characterized by humoral and cellular markers, we developed a lateral flow test measuring multiple host proteins based on six previously identified biomarkers for various leprosy phenotypes. This multi-biomarker test (MBT) demonstrated feasibility of quantitative detection of six host serum proteins simultaneously, jointly allowing discrimination of patients with multibacillary and paucibacillary leprosy from control individuals in high and low leprosy endemic areas. Pilot testing of fingerstick blood showed similar MBT performance in point-of-care (POC) settings as observed for plasma and serum. Thus, this newly developed prototype MBT measures six biomarkers covering immunity against M. leprae across the leprosy spectrum. The MBT thereby provides the basis for immunodiagnostic POC tests for leprosy with potential for other (infectious) diseases as well.

6.
Clin Biochem ; 66: 76-82, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30695682

RESUMEN

OBJECTIVES: New user-friendly diagnostic tests for detection of individuals infected by Mycobacterium leprae (M. leprae), the causative pathogen of leprosy, can help guide therapeutic and prophylactic treatment, thus positively contributing to clinical outcome and reduction of transmission. To facilitate point-of-care testing without the presence of phlebotomists, the use of fingerstick blood (FSB) rather than whole blood-derived serum is preferred. This study is a first proof-of-principle validating that previously described rapid serum tests detecting antibodies and cytokines can also be used with FSB. METHODS: Quantitative detection of previously identified biomarkers for leprosy and M. leprae infection, anti-M. leprae PGL-I IgM antibodies (αPGL-I), IP-10 and CRP, was performed with lateral flow (LF) strips utilizing luminescent up-converting reporter particles (UCP) and a portable reader generating unbiased read-outs. Precise amounts of FSB samples were collected using disposable heparinized capillaries. Biomarker levels in paired FSB and serum samples were determined using UCP-LF test strips for leprosy patients and controls in Bangladesh, Brazil, South-Africa and the Netherlands. RESULTS: Correlations between serum and FSB from the same individuals for αPGL-I, CRP and IP-10 were highly significant (p < .0001) even after FSB samples had been frozen. The αPGL-I FSB test was able to correctly identify all multibacillary leprosy patients presenting a good quantitative correlation with the bacterial index. CONCLUSIONS: Reader-assisted, quantitative UCP-LF tests for the detection of humoral and cellular biomarkers for M. leprae infection, are compatible with FSB. This allows near-patient testing for M. leprae infection and immunomonitoring of treatment without highly trained staff. On site availability of test-result concedes immediate initiation of appropriate counselling and treatment. Alternatively, the UCP-LF format allows frozen storage of FSB samples compatible with deferred testing in central laboratories.


Asunto(s)
Anticuerpos/sangre , Análisis Químico de la Sangre/métodos , Proteína C-Reactiva/análisis , Quimiocina CXCL10/sangre , Lepra/diagnóstico , Resinas Acrílicas/química , Animales , Anticuerpos/inmunología , Antígenos Bacterianos/inmunología , Biomarcadores/sangre , Análisis Químico de la Sangre/instrumentación , Femenino , Cabras , Humanos , Rayos Infrarrojos , Masculino , Ratones , Mycobacterium leprae/inmunología , Nanopartículas/química , Nanopartículas/efectos de la radiación , Pruebas en el Punto de Atención
7.
Sci Rep ; 8(1): 17920, 2018 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-30560920

RESUMEN

Leprosy remains persistently endemic in several low- or middle income countries. Transmission is still ongoing as indicated by the unabated rate of leprosy new case detection, illustrating the insufficiency of current prevention methods. Therefore, low-complexity tools suitable for large scale screening efforts to specifically detect M. leprae infection and diagnose disease are required. Previously, we showed that combined detection of cellular and humoral markers, using field-friendly lateral flow assays (LFAs), increased diagnostic potential for detecting leprosy in Bangladesh compared to antibody serology alone. In the current study we assessed the diagnostic performance of similar LFAs in three other geographical settings in Asia, Africa and South-America with different leprosy endemicity. Levels of anti-PGL-I IgM antibody (humoral immunity), IP-10, CCL4 and CRP (cellular immunity) were measured in blood collected from leprosy patients, household contacts and healthy controls from each area. Combined detection of these biomarkers significantly improved the diagnostic potential, particularly for paucibacillary leprosy in all three regions, in line with data obtained in Bangladesh. These data hold promise for the use of low-complexity, multibiomarker LFAs as universal tools for more accurate detection of M. leprae infection and different phenotypes of clinical leprosy.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Antígenos Bacterianos/inmunología , Pruebas Inmunológicas/métodos , Lepra/diagnóstico , Mycobacterium leprae/inmunología , Adolescente , Adulto , Anciano , Brasil , Proteína C-Reactiva/metabolismo , Estudios de Casos y Controles , Quimiocina CCL4/sangre , Quimiocina CXCL10/sangre , Niño , China , Enfermedades Endémicas , Etiopía , Femenino , Humanos , Inmunidad Celular , Inmunidad Humoral , Lepra/sangre , Lepra/inmunología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Factores Socioeconómicos , Adulto Joven
8.
Sci Rep ; 7(1): 8868, 2017 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-28827673

RESUMEN

Early detection of leprosy is key to reduce the ongoing transmission. Antibodies directed against M. leprae PGL-I represent a useful biomarker for detecting multibacillary (MB) patients. Since efficient leprosy diagnosis requires field-friendly test conditions, we evaluated two rapid lateral flow assays (LFA) for detection of Mycobacterium leprae-specific antibodies: the visual immunogold OnSite Leprosy Ab Rapid test [Gold-LFA] and the quantitative, luminescent up-converting phosphor anti-PGL-I test [UCP-LFA]. Test performance was assessed in independent cohorts originating from three endemic areas. In the Philippine cohort comprising patients with high bacillary indices (BI; average:4,9), 94%(n = 161) of MB patients were identified by UCP-LFA and 78%(n = 133) by Gold-LFA. In the Bangladeshi cohort, including mainly MB patients with low BI (average:1), 41%(n = 14) and 44%(n = 15) were detected by UCP-LFA and Gold-LFA, respectively. In the third cohort of schoolchildren from a leprosy hyperendemic region in Brazil, both tests detected 28%(n = 17) seropositivity. Both rapid tests corresponded well with BI(p < 0.0001), with a fairly higher sensitivity obtained with the UCP-LFA assay. However, due to the spectral character of leprosy, additional, cellular biomarkers are required to detect patients with low BIs. Therefore, the UCP-LFA platform, which allows multiplexing with differential biomarkers, offers more cutting-edge potential for diagnosis across the whole leprosy spectrum.


Asunto(s)
Anticuerpos Antibacterianos/inmunología , Lepra/diagnóstico , Lepra/inmunología , Mycobacterium leprae/inmunología , Pruebas en el Punto de Atención , Pruebas Serológicas/métodos , Antígenos Bacterianos/inmunología , Biomarcadores , Brasil , Ensayo de Inmunoadsorción Enzimática , Humanos , Curva ROC
9.
Clin Vaccine Immunol ; 24(8)2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28592626

RESUMEN

Although rheumatoid arthritis (RA) is a chronic, persistent autoimmune disease, 10 to 15% of RA patients achieve sustained disease-modifying antirheumatic drug (DMARD)-free remission over time. The biological mechanisms underlying the resolution of persistent inflammation in RA are still unidentified, and there is a lack of prognostic markers. It is well established that increased serum levels of gamma interferon-induced protein 10 (IP-10) are associated with (acute) increased inflammatory responses (e.g., in leprosy). In order to assess the potential of IP-10 as a diagnostic tool for inflammatory episodes of RA, we performed a retrospective study and assessed IP-10 levels in longitudinally banked serum samples obtained from patients upon first diagnosis of RA. The selection consisted of 15 persistent RA patients and 19 patients who achieved DMARD-free sustained remission. IP-10 levels, measured by use of a user-friendly quantitative lateral flow assay (LFA), showed up to 170-fold variation interindividually, and baseline IP-10 levels could not be differentiated between the two patient groups. However, a difference in the change in IP-10 levels between the first and last visits (ΔIP-10) was observed (P = 0.003) between DMARD-free (median ΔIP-10, -662 pg/ml [decrease]) and persistent (median ΔIP-10, 468 pg/ml [increase]) RA patients. Moreover, intraindividual changes in IP-10 levels during the course of disease corresponded to the disease activity score (DAS) (P = 0.05). These data indicate that IP-10 is associated with disease activity and perseverance of RA. The association of IP-10 with DAS indicates that this tool may be a practical diagnostic aid to help in monitoring disease progression in RA patients and may also find applications in other chronic diseases with exacerbated inflammatory episodes.


Asunto(s)
Antirreumáticos/uso terapéutico , Artritis Reumatoide/sangre , Artritis Reumatoide/fisiopatología , Quimiocina CXCL10/sangre , Artritis Reumatoide/tratamiento farmacológico , Progresión de la Enfermedad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
10.
Sci Rep ; 6: 34260, 2016 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-27682181

RESUMEN

Leprosy is a debilitating, infectious disease caused by Mycobacterium leprae. Despite the availability of multidrug therapy, transmission is unremitting. Thus, early identification of M. leprae infection is essential to reduce transmission. The immune response to M. leprae is determined by host genetics, resulting in paucibacillary (PB) and multibacillary (MB) leprosy associated with dominant cellular or humoral immunity, respectively. This spectral pathology of leprosy compels detection of immunity to M. leprae to be based on multiple, diverse biomarkers. In this study we have applied quantitative user friendly lateral flow assays (LFAs) for four immune markers (anti-PGL-I antibodies, IL-10, CCL4 and IP-10) for whole blood samples from a longitudinal BCG vaccination field-trial in Bangladesh. Different biomarker profiles, in contrast to single markers, distinguished M. leprae infected from non-infected test groups, patients from household contacts (HHC) and endemic controls (EC), or MB from PB patients. The test protocol presented in this study merging detection of innate, adaptive cellular as well as humoral immunity, thus provides a convenient tool to measure specific biomarker profiles for M. leprae infection and leprosy utilizing a field-friendly technology.

11.
Clin Vaccine Immunol ; 23(6): 515-519, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27030588

RESUMEN

Acute inflammatory reactions represent the major cause of irreversible neuropathy in leprosy. These tissue-destroying episodes have considerable overlap with acute immunological complications (flares) in several chronic (autoimmune) diseases that similarly warrant early detection. However, the lack of diagnostic tests impedes early diagnosis of these reactions. Here, we evaluated a user-friendly multiplex lateral flow assay for the simultaneous detection of IP-10 and anti-phenolic glycolipid I antibodies for longitudinally monitoring early onset and treatment of leprosy reactions.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Antígenos Bacterianos/inmunología , Quimiocina CXCL10/sangre , Ensayo de Inmunoadsorción Enzimática , Glucolípidos/inmunología , Lepra/inmunología , Monitorización Inmunológica/métodos , Sistemas de Atención de Punto , Biomarcadores/sangre , Quimiocina CXCL10/inmunología , Diagnóstico Precoz , Humanos , Lepra/complicaciones , Lepra/terapia , Mycobacterium leprae/inmunología
12.
Clin Biochem ; 49(1-2): 22-31, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26285074

RESUMEN

OBJECTIVE: Multi-center evaluation of a user-friendly lateral flow test for detection of IP-10 and CCL4 levels in Mycobacterium tuberculosis (Mtb) antigen-stimulated whole blood samples from tuberculosis (TB) suspects. DESIGN AND METHODS: A quantitative lateral flow (LF)-based assay platform was applied to detect chemokines IP-10 and CCL4. Chemokine quantitation was achieved using interference-free, fluorescent up-converting phosphor (UCP) labels. The new assays allowed worldwide shipping and storage without requiring a cold chain and were tested at seven institutes (including Ethiopia, Malawi, The Gambia, South Africa, Uganda and Namibia) employing portable lightweight readers for detection of the UCP label. At each site, clinical samples, confirmed TB and non-TB (i.e. other respiratory diseases (ORD)) cases, were collected and analyzed simultaneously with quality control (QC) human IP-10 or CCL4 standards. RESULTS: Performance of the UCP-LF assay in Africa using QC standards indicated high robustness allowing quantitative detection between 100 and 100,000pg/mL. The optimized assays allowed successful determination of chemokine levels using 1µL whole blood sample from the locally recruited subjects with TB or ORD. CONCLUSION: This African multi-center trial further demonstrated the applicability of the low-tech and robust UCP-LF platform as a convenient quantitative assay for chemokine detection in whole blood. Ambient shipping and storage of all assay reagents and the availability of lightweight standalone readers were acknowledged as essential requirement for test implementation in particular in remote and resource-limited settings.


Asunto(s)
Quimiocina CCL4/sangre , Quimiocina CXCL10/sangre , Tuberculosis/sangre , Estudios de Casos y Controles , Humanos
13.
PLoS Negl Trop Dis ; 8(5): e2845, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24810599

RESUMEN

BACKGROUND: Field-applicable tests detecting asymptomatic Mycobacterium leprae (M. leprae) infection or predicting progression to leprosy, are urgently required. Since the outcome of M. leprae infection is determined by cellular- and humoral immunity, we aim to develop diagnostic tests detecting pro-/anti-inflammatory and regulatory cytokines as well as antibodies against M. leprae. Previously, we developed lateral flow assays (LFA) for detection of cytokines and anti-PGL-I antibodies. Here we evaluate progress of newly developed LFAs for applications in resource-poor settings. METHODS: The combined diagnostic value of IP-10, IL-10 and anti-PGL-I antibodies was tested using M. leprae-stimulated blood of leprosy patients and endemic controls (EC). For reduction of the overall test-to-result time the minimal whole blood assay time required to detect distinctive responses was investigated. To accommodate LFAs for field settings, dry-format LFAs for IP-10 and anti-PGL-I antibodies were developed allowing storage and shipment at ambient temperatures. Additionally, a multiplex LFA-format was applied for simultaneous detection of anti-PGL-I antibodies and IP-10. For improved sensitivity and quantitation upconverting phosphor (UCP) reporter technology was applied in all LFAs. RESULTS: Single and multiplex UCP-LFAs correlated well with ELISAs. The performance of dry reagent assays and portable, lightweight UCP-LF strip readers indicated excellent field-robustness. Notably, detection of IP-10 levels in stimulated samples allowed a reduction of the whole blood assay time from 24 h to 6 h. Moreover, IP-10/IL-10 ratios in unstimulated plasma differed significantly between patients and EC, indicating the feasibility to identify M. leprae infection in endemic areas. CONCLUSIONS: Dry-format UCP-LFAs are low-tech, robust assays allowing detection of relevant cytokines and antibodies in response to M. leprae in the field. The high levels of IP-10 and the required shorter whole blood assay time, render this cytokine useful to discriminate between leprosy patients and EC.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Antígenos Bacterianos/inmunología , Citocinas/sangre , Pruebas Inmunológicas/métodos , Lepra/diagnóstico , Lepra/inmunología , Mycobacterium leprae/inmunología , Citocinas/metabolismo , Humanos , Cinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...